8.3 Control display
Part names
Position
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
For more information, refer to the Control Display Operating Manual.
GEM, GEMJ – Fire-fighting Pump Set
1
2
3
Part number
Display
NFC (Near field communication) port
Navigation and setup buttons
LED showing the status of the start pressure
switches
Auto mode LED
Manual activation button
IR programming port (infrared)
Manual STOP button
Manual STOP LED
RESET button
LED RESET
Motor status LED
Pump LED
Power supply status LED
14
6
4
5
Description
Wireless programming port
Yellow = contact open, start request active
Red = automatic mode disabled
IR-USB programming port
On Yellow = STOP enabled
Alarm silencing
On = alarms active
Off = motor stopped
Green = motor running with current 10% above the rated current
Red = motor running with current 10% below the rated current
Shows
• the status of the motor control, or
• the status of the pump running pressure switch, if present
Green steady = pump running
Flashing = discrepancy between the status of the pressure switch and the
status of the motor
Green = mains voltage within the set parameters, correct phase sequence
Red = mains voltage outside the set parameters, wrong phase sequence
en – Original Instructions
13
12
11
10
8
7