Test function
090 Event memory
The alarm centre stores the last 250 events. Each event is
stored with date and time. The event memory can be viewed
via the program menu.
1. On the control unit, enter:
2. The LCD display shows the latest events first.
3. You can page forwards and backwards in the event
memory. Press key 1 to page forwards and key 3 to
page backwards.
4. Press
to switch between the event and the date.
5. Press
to exit the event memory.
6. The event memory cannot be deleted by the
programmer or the user.
Entries in the event memory and their meaning:
Entry
Meaning
MAINS Fail
Failure of 230V AC power supply
MAINS Fail
230V AC power supply restored
OK
Alarm Abort
Alarm aborted manually by user
AUX DC Fail
12V DC power supply failed or AUX fuse
defect
AUX DC Fail
12V DC power supply restored
OK
Bad
Error in alarm centre memory
Checksum
Batt Load Fail
Failure of battery charger or battery fuse
defect
Batt Load Fail
Battery charger restored
OK
Burg Zone nn
Zone nn has triggered a burglar alarm
Burg Zone nn
Zone nn OK
OK
Defaults
Factory settings restored
Loaded
EEPROM Fail
Memory error in the alarm centre
090
85
Fire Zone nn
Zone nn has triggered a fire alarm
Fire Zone nn
Zone nn reset
OK
Fire OK
Fire alarm reset
Excess Keys
A user has tried too often to enter code in
the control unit
Keyboard
Control unit nn failed
Missing
Keyboard
Control unit nn reconnected
Restore
Keyboard
Control unit has triggered a tamper alarm
Tamper
Keyboard
Control unit nn tamper reset
Restore
Fire Zone
Fire alarm triggered at control unit nn
Alarm
Medical Zone
Medical emergency alarm triggered at
Alarm
control unit nn
Key Sw Set #
Alarm centre activated via key switch of
zone nn
Entry
Meaning
Key Sw Unset
Alarm centre deactivated via key switch of
#
zone nn
Key Box Cls
Zone nn with key box property closed
Z#
Key Box Opn
Zone nn with key box property opened
Z#
Lid Tamper
The lid contact of the alarm centre was
triggered
Lid Tamper
The lid contact of the alarm centre is
Restore
closed again
Batt missing
Battery supply interrupted (cable not
plugged in)
Batt Flt Restore Battery supply restored (cable connected)
PA K -- Alarm
BDT nn has triggered a panic alarm
PA Z -- Alarm
Zone nn has triggered a panic alarm
PA Z -- Rstr
Panic alarm of zone nn reset
Set Fail Zone -
The alarm centre could not be activated
-
since ZN nn was triggered
Fire Z – Alarm
Zone nn has triggered a fire alarm
Fire Z -- Rstr
Zone nn fire alarm reset
Soak Fail Z --
Zone nn sensor test failed
UK