6. If there is a fault, the alarm centre displays it. Clear
the fault and repeat steps 1–4.
101 Call mode TWG
Proceed as follows to change the property of call mode
telephone dialler (TWG):
1. You must be in program mode.
2. On the control unit, enter:
3. The LCD display shows: 101: Comms=OFF
4. Via the keypad, select from the following items and
press:
Comms=OFF
The alarm centre does not use any
0
communication devices.
Comms=Single
Single report. The alarm centre reports to
a programmed telephone number
(command 115) with an access number
1
(command 117). The alarm centre dials
the number and attempts to establish a
connection to the central station (max. 15
attempts).
Comms=ALT
The alarm centre dials one of two
programmed numbers and attempts to
establish a connection to the central
station. If the attempt is unsuccessful then
2
the alarm centre dials the second of the
two numbers (max 15 attempts for each
number). If the connection is successful
and the alarm is confirmed then the
connection is subsequently closed.
Comms=Dual
Dual Report. As in item 2, 2 numbers are
dialled and an attempt is made to
establish a connection to the central
3
stations. However, both central stations
must have successfully confirmed the
alarm (max. 15 attempts until both have
successfully confirmed).
101
69
5. Confirm your input. On the control unit, enter:
6. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
103 Format Report
Proceed as follows to change the property of the format
report:
1. On the control unit, enter:
2. The LCD display shows: 126:Format=FF
3. Via the keypad, select from the following items and
press:
Format=FF
0
Fast format
Format=CID
1
Contact ID
Format=SIAI1
2
Scancom SIA Level I
Format=SIA2
Scancom SIA Level 2 (transmits no
3
time+date)
Format=SIA3
4
Scancom SIA Level 3
Format=XSIS3
5
Extended Scancom SIA Level 3
Format=Hbeep
Home „beep" No particular format. The
6
alarm centre dials a number and transmits
a „beep" See command 186.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
.