Precautions
!WARNING!
UK
To avoid fire and injury, please
observe the following:
• Securely fasten the device at a dry
location in the building.
• Ensure sufficient air circulation for
the alarm centre.
• Do not expose the device to
temperatures less than -10°C or
more than 55°C.
• The device is designed for indoor
use only.
• Humidity must not exceed 90%
(non-condensed).
• Make sure that no metal objects can
be pushed into the equipment from
outside.
• Ensure that the voltage is
disconnected when performing work
on the device.
!ATTENTION!
Please observe the following
regulations to ensure trouble-free
operation of your device.
• The alarm centre is supplied with
12V DC power by means of the
internal transformer.
• The transformer is connected to the
230VAC building mains by means
of a separate, electrically protected
line.
• Connection work to the building
mains is subject to country-specific
regulations.
• A 7Ah rechargeable battery supplies
emergency standby power.
• The maximum power consumption
of connected components must
never exceed 1A.
• Always replace fuses with fuses of
the same rating, never higher.
4
!IMPORTANT INFO!
Burglar alarm panels in general:
If the equipment is not correctly
installed, signals may be
misinterpreted and result in false
alarms.The costs resulting from the
deployment of rescue organisations,
e.g.:fire or police, are borne by the
operator of the equipment. Therefore
please read the instructions very
carefully and follow the installation
instructions for lines and components
precisely.