159 Inverting additional outputs
You can also invert the additional transistor outputs for
different applications. In inverted state, the voltage of +12V is
applied in active state – e.g.: for addressing a visual signal.
1. On the control unit, enter:
2. The LCD display shows: 159: INV Pgby OFF
3. Via the keypad, select from the following items and
press:
inv Pgby OFF
+12V voltage is removed for activating
00
the output. In deactivated state, the output
is set to +12V.
Inv Pgby ON
+12V voltage is applied for activating the
01
output. In deactivated state, the output is
set to ground.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
160 Time-confirmed alarm
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 160:Confrm t=30
3. Via the keypad, select from the following items and
press:
Bestät=000-999
The timer starts when an alarm has been
triggered for the first time. If another
000-
alarm is triggered before the time has
999
expired then the alarm centre transmits a
confirmed alarm to the central station
(command 89=1)
4. Confirm your input. On the control unit, enter:
161 Confirm internal loudspeaker
To change the settings:
159
.
160
.
77
1. On the control unit, enter:
2. The LCD display shows: 161:Conf Int OFF
3. Via the keypad, select from the following items and
press:
Conf Int OFF
Internal loudspeaker is on for unconfirmed
0
alarm (command 89=1)
Conf Int OFF
Internal loudspeaker is on for confirmed
1
alarm (command 89=1)
4. Confirm your input. On the control unit, enter:
162 Confirm external sirens
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 162:Conf Ext OFF
3. Via the keypad, select from the following items and
press:
Conf Ext OFF
External siren is on for unconfirmed alarm
0
(command 89=1)
Conf Ext ON
External siren is on for confirmed alarm
1
(command 89=1)
4. Confirm your input. On the control unit, enter:
163 Confirmed alarm during entry
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 163:Conf Ent Nev
3. Via the keypad, select from the following items and
press:
Conf Ent Nev
0
No alarm confirmation
Conf Ent 1
1
161
.
162
.
163