then the program code to delete the panic
alarm.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
035 First alarm reaction
Proceed as follows to change the property of the first alarm
reaction:
1. On the control unit, enter:
2. The LCD display shows: 035:Lock-out ON
3. Via the keypad, select from the following items and
press:
Lock-out ON
When the alarm time expires (alarm time
of the local alarm of the external siren),
0
the alarm centre is reactivated. The zone
that triggered the alarm is no longer
monitored.
Re-arm
When the alarm time expires (alarm time
of the local alarm of the external siren),
1
the alarm centre is reactivated. The zone
that triggered the alarm is monitored
again.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer mode.
036 Alarm cancellation
Sometimes users trigger a false alarm. To change the property
of the alarm cancellation:
1. On the control unit, enter:
2. The LCD display shows: 036: Abort OFF
3. Via the keypad, select from the following items and
press:
.
035
.
036
51
Abort OFF
0
Cancellation by the user is not allowed.
Abort ON
1
Users are allowed to cancel an alarm.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
037 Sabotage Report deactivated
To change this feature, proceed as follows:
1. On the control unit, enter:
2. The LCD display shows: 037:Day Tamp OFF
3. Via the keypad, select from the following items and
press:
Day Tamp OFF
In case of tampering when the alarm
0
centre is deactivated, this only issues an
internal alarm.
Day Tamp ON
In case of tampering when the alarm
centre is deactivated, this issues an
1
internal alarm and reports the tampering
to the central station.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
038 System Sabotage Reset
To change the property of the System Sabotage Reset:
4. On the control unit, enter:
5. The LCD display shows: 038: EnSysTmp ON
6. Via the keypad, select from the following items and
press:
EnSysTmp OFF
In the event of a system sabotage, you can
0
reset the alarm centre by entering the user
.
037
.
038
UK