4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
063 Alarm behaviour for internal active (B)
To change the alarm property for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 063: B=Keypad
3. Via the keypad, select from the following items and
press:
B=Keypad
0
Only the control units are activated.
B=Internal
On alarm, the control units and the
1
internal alarm are activated.
B=Local
On alarm, the control units, the internal
2
alarm and the external siren are activated.
B=Full
On alarm, the control units, the internal
3
signalling, the external sirens and the
telephone dialler are activated.
In a partitioned system
B=Keypad
0
Only the control units are activated.
B=Local
On alarm, the control units, the internal
1
alarm and the external siren are activated.
B=Full
On alarm, the control units, the internal
2
signalling, the external sirens and the
telephone dialler are activated.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
.
063
.
59
065 Exit delay time internal B
To change the property of the exit delay time for internal
active B:
1. On the control unit, enter:
2. The LCD display shows: 065: Exit B=20
3. Via the keypad, select from the following items and
press:
Exit B=10
Exit delay time for internal active B is 10
1
seconds.
Exit B=20
Exit delay time for internal active B is 20
2
seconds.
Exit B=30
Exit delay time for internal active B is 30
3
seconds.
Exit B=45
Exit delay time for internal active B is 45
4
seconds.
Exit B=60
Exit delay time for internal active B is 60
5
seconds.
Exit B=120
Exit delay time for internal active B is 120
6
seconds.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
066 Forbikobler partitions
To change this property (only possible in partitioned
systems):
1. On the control unit, enter:
2. The LCD display shows: 066:Forbi 1 abcd
3. Via the keypad, select from the following items and
press:
065
.
066
UK