Télécharger Imprimer la page

Abus TERXON M Instructions D'installation page 142

Publicité

Les langues disponibles

Les langues disponibles

After entering the zone name, enter the zone property. Zone
properties are explained on pages 19 and 20 of these
instructions. Enter the zone property as follows:
1. Enter the zone property via the keypad as follows:
UK
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
2. After entering the zone property, enter the area for
which this zone is to be monitored. For an
explanation of areas, see page 20 of these
instrauctinos. Enter the area via the keypad as
follows:
A
B
C
d
,
3. Apart from the zone property and the area in which
the zone is to be monitored, there are also zone
attributes. Via the keypad,
enter the zone attributes as follows:
X1
NU – Not Used
PA – Panic
Fr – Fire
NA – Immediate
24 – 24 hours
FE – Entry/exit
Er – Entry to follow
SA – Shock sensor (for SK/UK)
Tc – Technical zone
KB – Keybox (for SK)
SD – Fire alarm
KM – Key switch pulse
KF – Key switch stable
AM – Anti Mask (not with Terxon S)
FB – Forbikobler (SK only)
This zone is monitored if area A is active.
a
The LCD display shows:
This zone is monitored if area B is active.
b
The LCD display shows:
This zone is monitored if area C is active.
c
The LCD display shows:
This zone is monitored if area D is active.
d
The LCD display shows:
C – door chime
The alarm centre always generates a tone
on the control unit and the loudspeaker if
a zone with this zone attribute is triggered.
This applies only if the burglar alarm
centre is deactivated.
This zone is available for zones with the properties
"immediate", "entry/exit", "entry", "follow" and "shock
sensor".
S – Sensor test
Zones with this zone attribute are in a test
function. Use this test function if you think
a sensor may trigger a false alarm. This
zone starts a 14-day test. If this zone
triggers an alarm within 14 days, no
general alarm state is declared. The
sensor is removed from monitoring and a
X2
message is displayed.
If the zone triggers no alarm within 14
days, the zone test ends, the zone attribute
is deleted and the zone works normally
again.
This zone is available for zones with the properties
"immediate", "entry to follow", "technical" and "shock
sensor".
D – Zone link
Zones with this zone attribute first trigger
an alarm when a further zone triggers an
alarm with 5 minutes or if a zone is open
for at least 10 seconds (e.g.: magnetic
contacts). This function reduces false
X3
alarms from individual sensors to a
minimum, but a burglary may be detected
too late or not at all.
This zone is available for zones with the properties
"immediate", "entry to follow".
O – Lock zone
Zones with this zone attribute can be
X4
locked manually by the user and removed
from monitoring.
4. Apart from the zone properties and zone attributes,
you can make further settings for some zone
properties. For example, for an "entry/exit" zone and
46

Publicité

loading