077 Alarm behaviour for internal (D)
To change the alarm property for internal active (D):
1. On the control unit, enter:
2. The LCD display shows: 077: D = Internal
UK
3. Via the keypad, select from the following items and
press:
0
1
2
3
In a partitioned system
0
1
2
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
077
D=Keypad
Only the control units are activated.
D=Internal
On alarm, the control units and the
internal alarm are activated.
D=Local
On alarm, the control units, the internal
alarm and the external siren are activated.
D=Full
On alarm, the control units, the internal
signalling, the external sirens and the exits
are activated.
D=Keypad
Only the control units are activated.
D=Local
On alarm, the control units, the internal
alarm and external sirens are activated.
D=Full
Control unit + internal + external +
telephone dialler
079 Exit delay time internal D
To change the property of the exit delay time for internal
active D:
1. On the control unit, enter:
2. The LCD display shows: 079: Exit D=10
3. Via the keypad, select from the following items and
press:
Exit D=10
Exit delay time for
1
internal active D: 10 seconds.
Exit D=20
Exit delay time for
2
internal active D: 20 seconds.
Exit D=30
Exit delay time for
3
internal active D: 30 seconds.
Exit D=45
Exit delay time for
4
internal active D: 45 seconds.
Exit D=60
Exit delay time for
5
internal active D: 60 seconds.
Exit D=120
Exit delay time for
6
internal active D: 120 seconds.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
.
double "beep" tone and shows Installer Mode.
080 Forbikobler door bell
Proceed as follows to change the property of the Forbikobler
door bell:
1. On the control unit, enter:
2. The LCD display shows: 080: Chime OFF
3. Via the keypad, select from the following items and
press:
64
079
.
080