4. Confirm your input. On the control unit, enter:
UK
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
087 Control unit alarm
To change the properties of the connected control units:
1. On the control unit, enter:
2. The LCD display shows: 087:Dual Key OFF
3. Via the keypad, select from the following items and
press:
0
1
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
089 Alarm confirmation
To change the properties:
1. On the control unit, enter:
2. The LCD display shows: 089:Confirm OFF
3. Via the keypad, select from the following items and
press:
expiry of the delay time. The user has
another 30 seconds to enter the user code
and deactivate the alarm centre.
087
Dual Key OFF
If the function is deactivated, no alarm
can be emitted by the control unit.
Dual Key ON
If the function is activated, an alarm can
be emitted by the control unit. To trigger
an alarm, press the following keys:
1 & 3 for panic
4 & 6 for medical emergency
7 & 9 for fire alarm
For further information, see the operating
instructions of this product.
089
Confirm OFF
The alarm centre is not programmed for
0
the signalling of confirmed alarms.
Confirm ON
The alarm centre is programmed for the
.
1
signalling of confirmed alarms.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
090 - 097 Test function: see section 5
098 Factory settings
To restore the factory settings:
1. You must be in program mode.
2. On the control unit, enter:
3. The LCD display shows: 098: Load Default
4. On the control unit, enter:
5. To restore the factory settings, press the following
key:
.
6. To abort, press:
7. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
.
099 Exit program mode
To exit program mode:
1. On the control unit, enter:
2. The LCD display shows: 099: exit Eng ?
3. On the control unit, enter:
4. The control unit shows: SYSTEM TEST
5. If no fault exists and zones with the properties 24
hour, fire, panic or technical open are closed, you
exit the program menu.
68
.
098
1
.
099