Now we program additional transistor outputs for the LEDs of
the key switch. The yellow LED should light in deactivated
alarm state, and the red LED in activated alarm state of the
alarm system. To program the first additional transistor output
OP4 or the state of the red LED, enter 151 on the keypad.
Confirm your input by pressing the Enter key
You see the
Enter 13 to change the setting to "Open". The display
changes to:
Confirm your input with
.
The transistor output OP5 – item 152 in the programming
menu – has to be adjusted on "CLOSE" (14). Note that
changes do not take effect until you exit the programm-
ing menu.
The yellow LED now lights permanently when the alarm system
is deactivated, and switches off when it is activated. The red
LED shows whether the system is activated.
The following describes the settings of relais outputs 1 and 2
for the siren and the flashlight of the SG1650.
Enter 081 on the keypad and confirm with
following display appears:
Please change the setting to Strobe. Enter 08 and press
This first resets the flashlight when you deactivate the alarm
system.
Relais output 2 must be set to "Bell". To do this, select menu
item 083 and verify with
. Enter 00 and
exit to "Bell".
To change the siren delay, enter 041 in the programming
menu and press the Enter key
If required, you can change the siren delay. You can select
values from 0 to 20 min.
.
following:
. The
.
to set the
. The display shows:
27
For the siren duration, you can select values from 1.5 min. to
20 min.
Select the programming item 042 and confirm with
see the following display:
We recommend that you keep this value or reduce it to 1.5
minutes (in Germany, the siren duration must not exceed 3
minutes).
Before defining users, test the alarm system functions. Start by
testing the relais/transistor outputs. Enter 091 in the
programming menu and press
You now have a connection between NO1 and C1.
If you now press
again, the output is reset. Under menu
items 092 and 093, you can test outputs 2 and OP3.
In the next step, check that the control unit buzzer is
functioning properly. Select menu item 095 and press
You see the following display:
At the same time, you hear a constant buzzer tone. The buzzer
is working. Confirm with
.
Finally, test the functionality of the sensors. Do this under
menu item 097. After entering this item, press the Enter key
. You see the following display:
Now open Zone 02. You hear a double tone and see the
following display:
Close the zone
again to end the sensor test. Run the same test for the other
sensors.
If you use a loudspeaker with the system, you can test it in the
programming menu under item 094.
. You
.
.
and press
UK