2. The LCD display shows: 118:DL Tel No 1
3. Via the keypad, enter the telephone number.
Use key
to enter a 4-second pause (shown by a
A
comma).
u
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
119 RemoteTel No 2
See command 118.
120 RemoteTel No 3
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 120:DL No 3=OFF
3. Via the keypad, select from the following items and
press:
DL No 3=OFF
The alarm centre does not just accept any
0
remote telephone number.
DL No 3=ON
The alarm centre accepts any numbers
from remote PCs. The remote PC transmits
1
its number to the alarm centre and the
alarm centre uses this number for the call
back.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer mode.
123 Reset report
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 123:Restore OFF
3. Via the keypad, select from the following items and
press:
.
120
.
123
73
Restore OFF
The alarm centre does not communicate
0
any resets.
Restore ON
The alarm centre communicates resets.
1
(Function only with Scancom Fast Format)
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
124 Switch open/close
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 124:Rev O/C OFF
3. Via the keypad, select from the following items and
press:
Rev O/C OFF
0
Open/Close not switched
Rev O/C ON
The function switches the commands
1
Open/Close for Scancom Fast Format.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
125 No signal „closed"
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 125:Omit > 1 OFF
3. Via the keypad, select from the following items and
press:
Omit >1 OFF
0
Omit >1 ON
The alarm centre does not transmit the
„closed" signal if more than 1 zone is
1
locked.
(Function only with Scancom Fast Format)
.
124
.
125
UK