5.2.2 PEB 2X60 OPERATION
2. prepare the mixture in B, then press the desired pasteurization pushbutton on the
pushbutton panel located on this tank (or the SEMI-AUTOMATIC cycle), which
intermittently lights up to show that tank B is in STAND-BY.
3. when tank A has reached the programmed temperature and started up the cooling
phase, the selected pasteurization cycle led in tank B will light up and remain fixed,
to show the beginning of the heating cycle for tank B, while tank A continues
cooling.
4. when tank A has completed the pasteurization cycle (or AUTOMATIC cycle), the
compressor and the mixer in tank B keep on working until the selected cycle for this
tank is completed
17 - ENGLISH
The machine is equipped with two microprocessor and
two pushbutton panels, one for each tank. Working with
a single tank, PEB2X60 operation is the same as PEB
60.
Working with two tanks, it is necessary to proceed as
follows:
1. prepare the mixture in tank A, then press the selected
pasteurization cycle (or the SEMI-AUTOMATIC cycle), to
start up the AUTOMATIC cycle;
.