15.4. SET UP - UNBALANCE ROUNDING-OFF

The machine may be set to display the unbalance values in five-gramme increments i.e.
rounded to the nearest multiple of five (or quarters of an ounce if displayed in ounces) or
rounded to the gram (or tenth of an ounce if displayed in ounces).
Proceed as follows to modify this configuration:
- press the
- use the
- press the
- use the
Oun 0.25 (if the ounce display mode is activated)
- press the
Gr 1
to activate the unbalance display rounded to the gram
or Gr 5 to activate the unbalance display rounded to the nearest multiple of five
If the ounce display mode is active
or Oun 0.25
to activate the unbalance display rounded to a quarter of an ounce
Oun 0.10
to activate the unbalance display rounded to a tenth of an ounce
- press the
15.5. AUTOMATIC POSITION SEARCH (RPA)
When the automatic position search programme is activated, the machine stops the wheel
in the position for application of the outer side weight at the end of every balancing spin;
if it is equal to zero, the wheel is stopped in the inner side weight application position.
Press the
button to search for the second side position with the guard raised.
Proceed as follows to deactivate the automatic position search programme:
- press the
108
key
keys to search for SEt UP
key to confirm
keys to search for Gr 5 (if the gram display mode is activated) or
key to change the setting:
key to confirm and exit.
key
S 62 E Operator's manual