External Mechanical Sensor Calibration (If Installed) - SICE S 62 E Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

- Pressing the key
- THIS CALIBRATION IS VALID FOR ANY TYPE OF WHEEL!
17. EXTERNAL MECHANICAL SENSOR
CALIBRATION (IF INSTALLED)
This programme is used to calibrate the width sensor potentiometer. It must be performed
when the machine requests it by displaying the E4 message, or when the measured and
the actual rim widths differ.
Proceed as follows to recall this programme:
• press the
• use the
• press the
proceeding as follows:
1. The machine will display the following
message:
• CAL on the left display
• E flashing on the right display
2. Bring the automatic sensor arm into contact
with the wheel contact flange as shown in
Fig.25.
3. Press the key
4. Return the arm to the rest position
Notes:
If the calibration has been carried out successfully, a confirmation message will be displayed.
If the A20 message is displayed, the sensor position in the calibration phase is not correct.
Position it correctly, as already described, and repeat the procedure.
- Pressing the key
S 62 E Operator's manual
, it is possible to interrupt the programme at any time.
key
keys to search for GAU CAL
key to perform calibration,
to confirm the sensor position.
, it is possible to interrupt the programme at any time.
25
117