Programming code display

Code
description
h0
Awaiting setting
h1
Awaiting start of auto-programming
h2
Auto-programming mode - opening
h4
Auto-programming mode - closing
f0
Awaiting remote control memorisation for
operation in complete opening mode
f1
Awaiting remote control memorisation for
operation in pedestrian opening mode
f2
Awaiting remote control memorisation
for remote lighting control
f3
Awaiting remote control memorisation
for auxiliary output control

fault and breakdown code display

Code
description
E1
Cell safety autotest fault
E2
Programmable safety autotest fault The programmable safety input autotest is
E3
Defective safety edge autotest
E4
Obstacle detection when opening
E5
Obstacle detection when closing
E6
Cell safety fault
E7
Safety edge safety fault
E8
Programmable safety fault
E10
Motor short circuit protection
E13
Accessories power supply fault
E14
Intrusion fault
E15
Fault when the motor supplied by the
backup battery is first switched on

accessing memorised data

To access memorised data, select parameter "ud" then press "ok".
data
description
u0 to u1
Complete opening cycle
counter
u2 to u3
u6 to u7
Cycle counter with obstacle
detection
u8 to u9
u12 to u13
Pedestrian opening cycle counter
u14 to u15
Reset movement counter
u20
Number of monodirectional remote controls memorised for complete opening control
u21
Number of monodirectional remote controls memorised for pedestrian opening control
u22
Number of monodirectional remote controls memorised for remote lighting control
u23
Number of monodirectional remote controls memorised for auxiliary output control
d0 to d9
Log of the last 10 faults (d0 most recent - d9 oldest)
dd
To clear the fault log: press and hold "ok" for 7 s.
inputs/outputs short circuit protection
Non-operation of the product and the devices connected to terminals 21 to 26 (amber light, photoelectric cells (except bus), code keypad,
safety edge)
In case of a short circuit on terminals 21 to 26, no corresponding fault code will be displayed.
Check the device wiring and switch off the power supply during 10 seconds.
Nota: Accessories supply output = 1.2 A max.
Copyright © 2012 Somfy SAS. All rights reserved
Comments
Pressing and holding the "sEt" button for 2 seconds starts auto-programming mode.
Pressing the "ok" button starts the auto-programming cycle.
Pressing the "+" or "-" button allows the motor to be controlled in forced operation mode.
Pressing a button on the remote control allocates this button to the motor complete opening control.
Pressing "ProG" once more switches to "awaiting remote control memorisation for operation in pedestrian opening
mode: f1".
Pressing a button on the remote control allocates this button to the motor partial opening control.
Pressing "ProG" once more switches to "awaiting remote lighting control memorisation: f2".
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "ProG" once more switches to "awaiting auxiliary output control memorisation: f3".
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "ProG" once more switches to "awaiting remote control memorisation for operation in complete opening
mode: f0".
Comments
The cell autotest is not satisfactory.
not satisfactory.
The safety edge autotest is not satisfactory.
Detection in progress on safety input for
longer than 3 minutes.
The accessories power supply cuts
out following an overload (excessive
consumption)
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
since last auto-programming [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
global [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
since last auto-programming [Hundred thousands - ten thousands - thousands] [hundreds - tens - units]
solution?
Check that "P07" is correctly configured.
Check the wiring of the cells.
Check that "P09" is correctly configured.
Check the programmable safety input wiring.
Check that "P08" is correctly configured.
Check the safety edge wiring.
Check that no obstacles are causing the cells or safety edge to detect.
Check that "P07", "P08" or "P09" is correctly configured in relation to the
device connected to the safety input.
Check the safety device wiring.
Check that the photoelectric cells are correctly aligned.
Disconnect the backup battery and connect the motor to the mains to switch
it on for the first time.