Operating Test; Complete Opening Operation; Obstacle Detection Operation; Operation Of The Photoelectric Cells - SOMFY ELIXO 500 3S io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO 500 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 500 3S io
Auto-programming can be interrupted by:
• activating a safety input (photoelectric cells, etc.)
• the appearance of a technical fault (thermal protection, etc.)
• pressing a control button (motor electronics, memorised remote control, wired control point, etc.).
In case of interruption, the display indicates "h0" and the motor returns to "awaiting setting" mode.
During auto-programming, if the gate is stationary, pressing "sEt" will exit auto-programming mode.
Note: It is possible to access auto-programming mode at any time including when the auto-programming cycle has already been completed and the
display indicates "C1".

oPEratiNG tEst

Complete opening operation

C4

obstacle detection operation

Obstacle detection when opening = stop + partial reversal.
Obstacle detection when closing = stop + complete reopening.

operation of the photoelectric cells

with the photoelectric cells connected to the dry/Cell contact (terminals 19-20) and Cell safety input parameter P07 = 1.
Cells obscured with gate closed/open = the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
Cells obscured when opening = the state of the cells is not taken into account and the gate continues to move.
Cells obscured when closing = stop + complete reopening.

safety edge operation (closing only)

Activation of the safety edge when closing = stop + complete reopening.

Specific operation

See the user booklet.
8
C2
STOP
STOP
C2
Copyright © 2012 Somfy SAS. All rights reserved