QuiCk CommissioNiNG

memorising the keygo io remote controls for operation in complete opening mode

If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
[1]. Press and hold the "ProG" button (2 s) on the programming interface.
The screen displays "F0".
[2]. Press the outer left and right buttons on the remote control together.
The remote control indicator light flashes.
[3]. Press the button of the remote control that will open the gate fully.
The screen displays "Add".

auto-programming

Auto-programming allows the gate's speed, maximum torque and slowdown zones to be adjusted.
- Auto programming the gate's travel is essential when commissioning the motor.
- The gate must be in the intermediate position before auto-programming starts.
-
During auto-programming, the obstacle detection function is not active. Remove any objects or obstacles and do not allow any
persons near or inside the operating range of the motorisation.
To carry out an emergency stop during self-learning, use a stored remote control.
start auto-programming
[1]. Press and hold the "sEt" button (2 s).
Release the button when the screen displays "h1".
[2]. Press "ok" to start auto-programming.
Auto-programming must start with the gate being opened.
The gate performs two complete Opening and Closing cycles.
[1]
2 s
2 s
h0
h1
• If auto-programming starts with the gate being closed, stop auto-programming,
push the slide as shown opposite then restart auto-programming.
• If auto-programming is correct, the display indicates "C1".
• If auto-programming has not completed correctly, the display indicates "h0".
Copyright © 2012 Somfy SAS. All rights reserved
[2]
[1]
[2]
2 s
h0
f0
h2
h4
h2
C1
h4
h0
Elixo 500 3S io
[3]
add
h0
Auto-programming correct
Auto-programming incorrect