keytis io remote control general reset

Press the "ProG" and "kEy" buttons together. This causes:
• the programming to be completely cleared (all buttons),
• all the settings on the remote control to be cleared (refer to the instructions for the Keytis io
remote control),
• the system key memorised by the remote control to be modified.

Clearing all settings

Clears the auto-programming and resets the default values for all parameters.

loCkiNG thE ProGrammiNG buttoNs

Locks the programming (end limits, auto-programming, parameter settings).
When the programming buttons are locked, a dot appears after the 1st digit.
Press the "sEt", "+" and "-" buttons simultaneously.
- the "sEt" button must be pressed first.
- the "+" and "-" buttons must be pressed within 2 seconds.
To access the programming again, repeat this procedure.

diaGNostiCs

operating code display

Code
description
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate closure
C4
Gate closing
C6
Detection in progress for cell safety
C7
Detection in progress for safety edge
safety
C8
Detection in progress for programmable
safety
C9
Detection in progress for emergency
stop safety
C12
Reinjecting current
C13
Safety device autotest in progress
C14
Permanent complete opening wire
control input
C15
Permanent pedestrian opening wire
control input
C16
BUS cell programming refused
Cc1
9.6 V power supply
Cu1
24 V power supply
20
+
+
Comments
Automatic closing time delay P02, P04 or P05 in progress.
Displayed during a movement request or during movement when detection is in progress on the safety input.
The display appears for as long as detection is in progress on the safety input.
Displayed while the autotest is running on the safety devices.
Indicates that the complete opening wire control input is permanently activated (contact closed). Commands coming
from the radio remote controls are then disabled.
Indicates that the pedestrian opening wire control input is permanently activated (contact closed). Commands coming
from the radio remote controls are then disabled.
Check that the BUS cells (wiring, alignment, etc.) are operating correctly
Displayed during operation with 9.6 V backup battery
Displayed during operation with 24 V backup battery
C1
7 s
C.1
C1