oPERAtING tEst
opening the gate by hand
If necessary, the motor drive unit is provided with a release key so that the gate section can be moved by hand.
[1] After lifting the lock cover, insert the release key and turn it clockwise by 90°.
[2] Push the gate section by hand to open the gate.
[3] Turn the release key in the opposite direction to return to motor driven operation.
[4] Refit the lock cover.
checking operation
Before starting up the motor drive unit:
• Check that all components are solidly mounted
• Check all safety mechanisms for correct operation
• Check the emergency operation control
• Check that the electronic controller is operating correctly.
What do I do if the motor drive unit fails?
• Use a suitable instrument to check for the presence of voltage on the ends of the motor reduction gear unit after an
opening or closing operation.
• If the drive rod does not turn in the right direction, reverse the electrical operating connections on the motor reduction
gear unit.
sPEcIFIcAtIoNs
Power supply
Rotation speed
Power consumption
Current consumption
Push and pull torque
Useful travel
Drive rod speed
Manual operation
Nbr. of operations per 24 hours
Maximum gate section length
Maximum gate section weight
Ambient conditions
Protection level
Lubrication
8
230 V version
230 V AC
2800 rpm
210 W
0.8 A
2000 N
410 mm
14 mm/s
By unlocking key
60 operations
4000 mm
400 kg
-20°C to +60°C
IP44
Greased for life
Copyright © 2009 Somfy SAS. All rights reserved.