4.4. Auto-programming the door travel

Auto-programming allows the door's speed, maximum torque and
slowdown zones to be adjusted.
Attention
• Auto-programming is a mandatory step in commissioning the
motorisation.
• During auto-programming, the obstacle detection function is not
active. Remove any objects or obstacles and do not allow any
persons near or inside the operating range of the motorisation.
• During auto-programming, pressing the "SET", "+" or "-" button
interrupts auto-programming.
• During auto-programming, the safety inputs are active.
The slowdown zones when opening and closing are set to a default
distance of about 20 cm.
The door must not encounter any point of resistance in the slowdown
zone.
Attention
Once installation is complete, it is essential to check that the obsta-
cle detection complies with annex A of the standard EN 12 453.
4.4.1. Auto-programming a sectional or up-and-over
garage door - Fig. 19A
1) Press and hold the "SET" button for 2 s.
The "POWER" indicator light flashes quickly.
2) Control the motor with button "+" or "-" so that the transmission shuttle
is engaged on the carriage then bring the door to the closed position.
3) Adjuster the closed position using the "+" or "-" button.
Release the "-" button before forcing the motor on the door.
4) Press the "SET" button to confirm the closing end limit and start auto-
programming:
• The door opens at reduced speed.
• The door closes at nominal speed then reduced speed until it
reaches the closed position.
• The door opens at nominal speed then reduced speed until it reaches
the open position.
• The door closes at nominal speed then reduced speed until it
reaches the closed position.
Programming is complete. The "POWER" indicator is permanently lit.
4.4.2. Auto-programming a side garage door - Fig. 19B
Check the direction of rotation of the motor
1) Press and hold the "SET" button for 2 s.
The "POWER" indicator light flashes quickly.
2) Control the motor with button "+" or "-" so that the transmission shuttle
is engaged on the carriage then bring the door to the closed position.
3) Press and hold the "+" button to open the door.
If the door closes, press the "+" and "-" buttons at the same time. The
operating directing is reversed.
Starting auto-programming
4) Adjuster the closed position using the "+" or "-" button.
Release the "-" button before forcing the motor on the door.
5) Press the "SET" button to confirm the closing end limit and start auto-
programming:
• The door opens at reduced speed.
• The door closes at nominal speed then reduced speed until it
reaches the closed position.
• The door opens at nominal speed then reduced speed until it reaches
the open position.
• The door closes at nominal speed then reduced speed until it
reaches the closed position.
Programming is complete. The "POWER" indicator is permanently lit.
6

5. OPERATING TEST

5.1. Complete opening operation - Fig. 20

5.2. Obstacle detection operation

• Obstacle detection when closing = stop + complete reopening.
• Obstacle detection when opening = stop + partial reversal.

5.3. Operation of the photoelectric cells

• Cells obscured when opening = the state of the cells is not taken into
account and the door continues to move.
• Cells obscured when closing = stop + complete reopening.

5.4. Operation of the gate contact

• Activation of the gate contact when closing = stop
• Activation of the gate contact when opening = stop
5.5. Specific operation
See the user booklet.

5.6. User training

Train all uses in how to use this motorised door safely (standard use and
locking principle) and on the mandatory periodic checks.

6. CONNECTING ADDITIONAL DEVICES

Warning
The connection operations must be performed with the power off.

6.1. General wiring diagram - Fig. 21

Terminals
Connection
1
L
230 V power supply
2
N
3
Aux
Area lighting
4
Dry contact
5
Flash
24 V - 15 W orange
light output
6
7
-
24 V accessories
power supply
8
+
9
Tx
Power supply for pho-
toelectric cell trans-
mitter for auto-test
10
Batt
Battery
11
12
Start
Complete opening
control input
13
Common
14
Stop
Gate contact
15
16
Not used
17
Common
18
Cell
Cell safety input
19
Ant
Antenna earth
20
Antenna core
DEXXO SMART io
Comments
Max. 230 V - 500 W
• either 5 fluocompact or
LED lights
• or 2 power supplies for
low-voltage LEDs
• or 1 halogen light, max.
500 W
Compatible with 9.6 V
battery
NO dry contact
NO dry contact
NO dry contact
©