Operating Test; Total Opening Operation; Photoelectric Cells Operation; Gate Contact Operation - SOMFY Dexxo Smart 800 io Manuel D'installation

Masquer les pouces Voir aussi pour Dexxo Smart 800 io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
4.4.2
Auto-programming a side garage door
> > > Illustration 20
NOTICE
The door position at the end of auto-programming may be different from
the initial position.
1] Press the "SET" button (≈ 2 s) until the integrated lighting and the "SET"
indicator light flash quickly.
2] Actuate the motor using the "+" or "-" button to engage the transfer
shuttle on the trolley.
3] Check that pressing the "-" button causes the doorto close. If the door
opens, press the "+" and "-" buttons simultaneously to reverse the dir-
ection of operation.
4] Close by continuing to press the "-" button. Adjust the closed position
using the "+" or "-" button. Release before forcing the door.
5] Press the "SET" button to start auto-programming:
ð The closing position has been memorised.
ð The door opens at reduced speed.
ð The door closes at nominal speed, then reduced speed until it
reaches the memorised closed position (closing force limited to
400 N).
ð The door opens at nominal speed then reduced speed until it
reaches the open position.
ð The door closes at nominal speed, then reduced speed until it
reaches the memorised closed position (closing force limited to
400 N).
è Programming is complete. The "SET" indicator light is lit con-
stantly.
5

OPERATING TEST

5.1

Total opening operation

> > > Illustration 21
5.2

Photoelectric cells operation

Cells obscured when opening = the state of the cells is disregarded, and the
door continues to move.
Cells obscured when closing = stop + complete reopening.
If the cells are blocked for 3 minutes or more, the system switches to "wired
dead man" mode. In this mode, a command via a wired input causes the door
to move slowly.
The door moves for as long as the command is issued and stops immediately
when the command is discontinued. The system switches back to normal
mode as soon as the cells are no longer blocked.
CAUTION
"Wired deadman" mode requires the use of a safety contact (e.g. keyed re-
versing switch, ref. 1841036).
5.3

Gate contact operation

• Activation of the gate contact when closing = stop
• Activation of the gate contact when opening = stop
5.4

Specific modes

See the user booklet.
5.5

User training

Train all users in how to use this motorised door safely (standard use and
locking principle) and in the mandatory periodic checks.
6

CONNECTING PERIPHERALS

WARNING
The connection operations must be performed with the power off.
6.1

General wiring diagram

> > > Illustration 22
20
Terminals
Connection
1
L
230 V power supply
2
N
3
Aux
Area lighting
4
Dry contact
5
Flash
24 V - 15 W orange
light output
6
7
-
24 V accessories
power supply
8
+
9
Tx
Power supply for
photoelectric cell
transmitter for auto-
test
10
Batt
Battery
11
12
Start
Complete opening
control input
13
Common
14
Stop
Gate contact
15
16
Not used
17
Common
18
Cell
Cell safety input
19
Ant
Antenna earth
20
Antenna core
6.2

Description of the various peripherals

6.2.1
Photoelectric cells
Operating without photoelectric cells (default factory
configuration)
• Bridge present between terminals 17 and 18.
• Default parameter P4 = 1.
Standard cells without auto-test
> > > Illustration 23
1] Remove the bridge between terminals 17 and 18.
2] Wire the cells.
3] Program P4=1.
Standard cells with auto-test via power supply switching
> > > Illustration 24
WARNING
The installation of this type of cell is mandatory in case of operation in re-
mote control mode with automatic closing (P0=2 or 3).
1] Remove the bridge between terminals 17 and 18.
2] Wire the cells.
3] Program P4=3.
2-wire bus cells
> > > Illustration 25
1] Remove the bridge between terminals 17 and 18.
2] Wire the cells.
3] Program P4=2.
4] Perform a new auto-programming process (see Auto-programming the
door travel [} p.19]).
Copyright
Dexxo Smart 800 io / Dexxo Smart 1000 io
Comments
Max. 230 V - 500 W
• either 5 fluocom-
pact or LED lights
• or 2 power supplies
for
low-voltage
LEDs
• or 1 halogen light,
max. 500 W
Compatible with 9.6 V
battery
NO dry contact
NO dry contact
NO dry contact
©