Programming; Programming Button Description; End Limit Setting And Self-Learning - Fig; Memorising The Remote Controls For Operation In «Total Opening» Mode - Fig - SOMFY Dexxo Pro 800 RTS Manuel D'installation

Masquer les pouces Voir aussi pour Dexxo Pro 800 RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Dexxo Pro RTS
Fitting the chain retainer pads (Fig. 13)
For chain rails only.
These pads are used to limit spurious noise linked to chain friction within the rail. Position each
of the pads in the first hole in the rail a er the travel stop.
Make sure that the pad is pressed in all the way so that its positioning pin is accessible outside
of the rail.
Checking the chain or belt tension (Fig. 14)
The rails are supplied ready tensioned and inspected. If necessary, adjust the tensioning.
The rubber or tension spring must never be fully compressed during operation.
Connecting the mains power supply (Fig. 15)
[1]. Remove the motor cover.
[2]. Connect to the mains supply.
Plug the power cable into a suitable power outlet that complies with electric
power requirements.

4 PROGRAMMING

4.1 Programming button description

Buttons
Function
- Press for 2 s: memorise remote controls
- Press for 7 s: delete remote controls
- Press for 0.5 s: call up and exit the setup menu
- Press for 2 s: start learning
- Press for 7 s: clear learning and settings
- Stop learning
- Selecting a setting
- Modifying a setting value
- Using the forced mode
- Start the learning cycle
- Confirm setting selection
- Confirm setting value

4.2 End limit setting and self-learning - Fig. 16

For swinging doors, change the P9 setting before starting self-learning.
[1]. Press the "SET" button until the light comes on (2 s).
The display shows "S2"
[2]. Control the motor using the "+" or "-" buttons so that the transmission system runner
moves to link up with the trolley and closes the door.
- Pressing and holding the "-" button closes the door.
Release the "-" button before the motor has time to force against the door.
- Pressing and holding the "+" button opens the door.
[3]. Adjust the closed position using the "+" or "-" buttons.
Release the "-" button before the motor has time to force against the door.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
[4]. Press "OK" to validate the closed end limit position and start the self-learning cycle.
The door runs through a complete Open Close cycle.
- If learning was correct, the display will show "C1".
- If the learning cycle was not completed correctly, the display will show "S1".
During the learning cycle:
- If the door is moving, pressing any button will stop the movement and interrupt the learning
mode.
- If the door is stopped, pressing "SET" once will exit the learning mode.
You can call up the learning mode at any time, even when the learning cycle has already been
executed and the display shows "C1".
At the end of installation, it must be checked that the obstacle detection complies with
annex A of the standard EN 12 453.
4.3 Memorising the remote controls for operation in «Total
opening» mode - Fig. 17
Up to 32 control channels can be stored.
Running this procedure for a previously stored channel will clear it.
At this stage in the installation process, the Dexxo Pro motor drive unit is ready to run.

5 OPERATING TEST

5.1 Using the remote controls - Fig. 18

5.2 Obstacle detection function - Fig. 19 et 20

The detection of an obstacle during door opening will stop the door (Fig. 19).
The detection of an obstacle during door closure will reopen the door (Fig. 20).
Make sure that obstacle detection works when the door encounters an obstacle 50 mm from
the ground.

5.3 Built in lighting operation

The light will come on every time the motor drive unit is operated. It will go out automatically
a er one minute once the door stops. This time delay is adjustable (See section 7). Repetitive
use will cause the lighting to be lit constantly which may result in the light being switched off
automatically due to thermal protection.

5.4 End-users training

The end-users must be imperatively instruct to the safety use of this motorised door (standard
use and manual release principle) as well as to periodic and compulsery checks.

6 CONNECTING PERIPHERALS

6.1 Description of the various peripherals - Fig. 21

Key.
Description
1
Orange light
2
Remote lighting
3
Code keypad
4
Keyswitch
5
Aerial
6
Battery
7
Pedestrian door safety kit
8
Photoelectric cells
9
Reflex type cells
10
Sensor bar
11
Siren
WARNING
EN
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dexxo pro 1000 rts

Table des Matières