c) Dosage through Binary Inputs and activated by EXT.MEM:
ALARM
4
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
"ALARM" PROMPT AT THE END OF A DOSAGE
The «ALARM» prompt will be displayed at the end of a dosage operation (irrespective of
the dosage option) if one or both valves are closed and if the controller detects that there
is still a flow condition after the time delay period before alarm triggering has elapsed.
Note: The alarm time delay must take account of any jet correction that may have been
entered (the fluid quantity which continues to flow after the closure of the valve).
a) Manual or automatic dosage activated by LOC.MANU, LOC.MEM or MEM+MANU:
ALARM
b) Dosage through Binary Inputs and activated by EXT.MEM or EXT [T]:
ALARM
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
5.1.2. «[T] ERROR» prompt
This error prompt only occurs in the «EXT.[T]» option. It is displayed during a dosage
operation if the duration of the pulse is greater than 300 seconds or if it is greater than the
duration necessary to deliver the relevant quantity.
It will also appear when the quantity to be delivered is greater than 100000 (l, m
if the quantity being delivered has reached 100000 (l, m
not been switched off.
T [ERROR]
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
**
RESET
Choice "Continue" can only
be made on keypad.
CONTINUE
Device ready for a new
ENTER
batch (see 4.3.1)
Device ready for a new
**
4
batch (see 4.3.2)
4
BATCH CONTROLLER 8025
Device ready for a new
**
4
batch (see 4.3.3)
**
221
4
3
, etc.) and when the pulse has
Device ready for a new batch
(see 4.3.3)
**
E-41-
Current batch
L
continues
3
, etc.) or