4 CONFIGURATION

4.3.5. Pause / reset function

A current dosage can be momentarily or definitively stopped (except mode EXT [T]).
a) Modes MEM+MANU, LOC.MEM, LOC.MANU:
Countdown of the
dosage operation in
progress
* When in mode MEM+MANU, LOC.MEM or LOC.MANU, you can also start the dosage
using the 'Start/Pause' Binary Data Input.
b) Mode EXT.MEM:
Countdown of the dosage
operation in progress
221
L
4
Pause
c) Mode EXT [T]:
221
L
4
Pause
(**) When in mode EXT.MEM or EXT [T], you can also press the Enter key on the keypad.
ENTER
221
L
*
**
CONTINUE
"zero" position: no
input is enabled
**
CONTINUE
Choice "Reset" can only be
made on keypad.
RESET
BATCH CONTROLLER 8025
CONTINUE
ENTER
*
ENTER
RESET
*
**
221
4
1
RESET
2
3
**
221
4
**
Device ready for a new batch
4
(see 4.3.3)
E-30-
Current batch
221
L
continues
Device ready for a new
batch (see 4.3.1)
Current batch
L
continues
Device ready for
**
a new batch