Type Key; Options; Scope Of Delivery; Accessories - Samson Control EC-L Manuel D'installation Et Mise En Service

Masquer les pouces Voir aussi pour Control EC-L:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
TRANSPORTATION AND STORAGE
• 1x input/pump for leakage detection via moisture
probe
• 1x digital input (External OFF) for remote deacti-
vation of all pumps
4.4.2. Outputs
• 1 x potential-free changeover contact for
collective fault signal
• 1 x potential-free changeover contact for
collective run signal
• 1 x potential-free normally closed contact for
individual fault signal (ESM) per pump
• 1 x potential-free normally open contact for
individual run signal per pump
• 1 x power output for connecting a signal lamp
• 1x analogue output 0 – 10 V for display of the
actual level value
4.4.3. Switchgear
Mains connection:
Mains frequency:
Max. current consumption:
Max. switching capacity:
Activation type:
Ambient/operating
temperature:
Storage temperature:
Max. relative humidity:
Protection class:
Control voltage:
Connection values for power
output
Housing material:
Electrical safety:

4.5. Type key

Example: EC-L 2x12A-MT34-DOL-WM-X
Version:
EC
EC = Easy Control switchgear for fixed-speed
pumps
L
Level-dependent control of pumps
2x
Max. number of pumps that can be connected
12A
Max. rated current in ampere per pump
Mains connection:
MT34
M = alternating current (1~220/230 V)
T34 = three-phase current (3~380/400 V)
DOL
Direct-on-line starting of pump
WM
Wall fixation
Versions:
EMS = without main switch (mains isolator must
X
be provided by the customer!)
IPS = with integrated pressure transducer for
direct connection of a dynamic pressure bell
Installation and operating instructions Salmson-Control EC-L
1~220/230 V, 3~380/400 V
50/60 Hz
12 A per pump
4 kW per pump
Direct
-30...+50 °C
-30...+60 °C
90 %, non-condensing
IP54
24 V DC
24 V DC, 4 VA
Polycarbonate, UV-resistant
Pollution degree II

4.6. Options

• Installation in an external switch cabinet

4.7. Scope of delivery

• Switchgear
• Installation and operating instructions

4.8. Accessories

• Float switch for wastewater and sewage free of
faeces
• Float switch for abrasive sewage containing
faeces
• Level sensors
• Level monitor
• Dynamic pressure bell and bubbling-through
system
• Horn 230 V, 50 Hz
• Flash light 230 V, 50 Hz
• Signal lamp 24 VDC or 230 V, 50 Hz
• Zener barrier
• Ex-rated cut-off relay
Accessories have to be ordered separately.

5. Transportation and storage

5.1. Delivery

On delivery, check immediately that the shipment
is complete and undamaged. If any parts are
damaged or missing, the transport company or
the manufacturer must be notified on the day of
delivery since claims made after this date cannot
be recognised. Damage to parts must be noted on
the freight documentation!

5.2. Transport

Only the packaging used by the manufacturer or
supplier may be used for transport. This normally
precludes the possibility of damage occurring
during transportation and storage. The packaging
should be stored in a safe place for reuse if the
product is frequently used at different locations.

5.3. Storage

On delivery, switchgears may be placed into tem-
porary storage for up to 1 year until use providing
the details below are observed.
The following should be taken into consideration
for storage:
• Place the packaged switchgear on a firm
subsurface.
• Our switchgears may be stored at -30 °C
to +60 °C at a max. relative humidity of 90 %
(non-condensing). The store room must be dry.
We recommend a frost-protected room for stor-
age with a temperature between 10°C and 25°C
and a relative humidity of 40% to 50%.
Avoid condensation!
• Seal the threaded cable connections securely to
prevent ingress of moisture.
• Connected power supply cables should be pro-
tected against kinking, damage, and moisture.
English
45

Publicité

Table des Matières
loading

Table des Matières