Corghi EM 9350 XLine Manuel D'utilisation page 136

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

interrupt the programme at any time.
- THIS CALIBRATION IS VALID FOR ANY TYPE OF WHEEL!
17. CALIBRATION OF THE ULTRASONIC
WIDTH SENSOR (IF INSTALLED)
Used to calibrate the ultrasonic sensor located on the wheel guard pipe (width). It must
be performed when the machine requests it by displaying the E4 message, or when the
measured and the actual rim widths differ.
Proceed as follows to recall this programme:
• press the
• use the
for GAU CAL
• press the
bration, proceeding as follows:
1. The machine will display the follow-
ing message:
• CAL on the left display
• E flashing on the right display
2. fix the calibration template in line with
the threaded hole on the shaft assembly
bell, using the M8 screw (A, fig.29) sup-
plied with the ultrasonic sensor;
3. use the wheel ring nut to bring the
template into contact with the shaft
assembly bell (fig.29);
4. press the
securing of the template;
5. Once confirmed, the message "CAL
rot" is shown on the display
6. slowly turn the template towards the
operator to automatically enable the
clamping brake (fig.30);
7. When template movement is complete,
the message "CAL CLO" will appear
on the display
8. slowly lower the wheel guard (fig.31);
the machine will automatically cali-
136
key
keys to search
key to perform cali-
key to confirm the
Operator's Manual EM 9350 - EM 9350 C XLine
29
30

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Em 9350 c xline

Table des Matières