in the ALU1 and ALU2 programmes, the unbalance displayed by the machine on the
outer side refers to the centre of gravity of the adhesive weight in line with the shaft
assembly support flange (fig. 22)
• Manually applied adhesive weights with laser device enabled (if provided)
- Select the first side to be balanced
- Turn the wheel until the central element of the corresponding position indicator lights
up together with the laser line
- Apply the indicated balancing weight in the position on the rim corresponding to 6
o'clock.
Some slight residual unbalances may remain at the end of the test spin due to the
considerable difference in shape that may be found on rims having the same rated
dimensions. Therefore modify the value and position the previously applied weights
for accurate wheel balancing.
9. APPLYING BALANCING WEIGHTS IN
ALU1P OR ALU2P PROGRAMMES
• Adhesive weights applied with a weight-holder device (if available), after modifying
the application position from 12 o'clock to CLIP in the "Adhesive weight application
position" set-up menu
1 Select the first side to be balanced
2 Turn the wheel until the central element of the corresponding position indicator lights
up. Keeping the wheel in position with the clamping brake, a display will now show the
quantity of the weight to be applied in gr/ounces and the other will display the distance
in mm alternatively to the plane identification abbreviation (A-1 for Inner Plane/A-2 for
Outer Plane)