ATTENTION
If the machine is to be installed outdoors, it must be properly protected from adverse
weather by a roof.
Place the tyre changer in the designated work position observing the minimum clear-
ances shown in figure 4.
Ambient conditions in the place of operation
- Relative humidity from 30% to 95% without condensation.
- Temperature range from 0°C to 50°C.
ATTENTION
The machine must not be operated in potentially explosive atmosphere.
ELECTRICAL AND PNEUMATIC HOOK-UPS
WARNING
All operations required for the electrical hook-up of the machine must be carried out
exclusively by a qualified electrician.
- The electrical supply must be suitably sized in relation to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the power supply hook-up point, so that volt-
age drops under full load do not exceed 4% (10% in the case of start-up) below the
rated voltage specified on the dataplate.
- The user must equip the machine with the following:
• a dedicated power plug in compliance with the relevant electrical safety standards;
• a type A and B suitable circuit-breaker (residual current set to 30 mA) on the mains
connection;
WARNING: only a type A and B differential security breaker of the specified kind will
be tripped correctly in response to all the failure currents which may occur on the
machine.
• power line fuses in accordance with specifications in the main wiring diagram of this
manual;
• a suitable earthing system installed on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
panel and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
For correct operation of the machine the compressed air supply line must provide a
pressure range from a minimum of 8 bar to a maximum of 16 bar.
NOTE
38
A 2030 - A 2025 - A 2020 - A 2015 - A 2005 operator's manual