7 - RESET AND FACTORY SETTINGS

7.1 - General system reset

To reset the system, hold down the 4 keys simultaneously for 2 sec. This operation is the
same as disconnecting the power, waiting for it to close down completely and supplying
power again. The reset does not delete the settings saved by the user.

7.2 - Factory settings

The device leaves the factory with a series of preset parameters which may be changed
according to the user's requirements. Each change of the settings is automatically saved
in the memory and, if desired, it is always possible to restore the factory conditions (see
Restoring the factory settings par par 7.3 - Restoring the factory settings).

7.3 - Restoring the factory settings

To restore the factory values, switch off the device, wait until the display has switched off
completely, press and hold down the "SET" and "˄" keys and turn on the power; release
the two keys only when the letters "EE" appear. This restores the factory settings (a mes-
sage and a rereading on EEPROM of the factory settings permanently saved in the FLASH
memory). Once all the parameters have been set, the device returns to normal operation.
NOTE: Once the factory values have been restored it will be necessary to reset all the
parameters that characterise the system (gains, setpoint pressure, etc.) as at the first in-
stallation.
Factory settings
Identifying code
Description
- One attempt every 10 minutes for a total of
6 attempts.
- One attempt every hour for a total of 24 at-
tempts.
- One attempt every 24 hours for a total of 30
attempts.
Value
Installation Memo
³
e.sybox mini
BK
Display brightness
TK
Backlight lighting T
LA
Language
SP
Setpoint pressure [bar]
Revs per minute in manual mode
RI
[rpm]
OD
Type of plant
RP
Pressure decrease to restart [bar]
MS
Measuring system
EK
Low pressure function on suction
Low pressure threshold on
PK
suction [bar]
TB
Blockage time for water lack [s]
T1
Low pr. delay [s]
T2
Delay in switching off [s]
Proportional gain
GP
coefficient
GI
Integral gain coefficient
RM
Maximum speed
AE
Anti-blocking function
AF
Antifreeze
PW
Change Password
AY
Anticycling Function AY
*: for products intended for specific markets, the factory value of the measurement system MS may be
1 (English speaking world)
Table 10: Factory settings
ENGLISH
80%
2 min
ENG
2,7
3200
1 (Rigid)
0,3
0 (International)*
2
0,5
15
8
30
0,5
1,2
7000
1(Enable)
0
0 (Disabled)
2 (SMART)
GB
62