(par. 5.5.1) in bar
So, by the manufacturer: Pair = 3.0 – 0.3 – 0.7 = 2.0 bar
If different values are set for the parameters SP and/or RP, regulate the valve of the ex-
pansion vessel releasing or letting in air until the above equation is satisfied again (e.g.:
SP=2.0bar; RP=0.3bar; release air from the expansion vessel until a pressure of 1.0 bar
is reached on the valve).
Failure to respect the above equation may lead to malfunctions of the system
or to premature breakage of the diaphragm inside the expansion vessel.
Considering the expansion vessel capacity of only 1 litres, any operation to
check the air pressure must be performed by connecting the pressure gauge
very rapidly: on small volumes the loss of even a limited quantity of air can
cause an appreciable drop in pressure. The quality of the expansion vessel
ensures the maintenance of the set air pressure value, proceed to check it only
at calibration or if you are sure of a malfunction.
Any operation to check and/or reset the air pressure must be performed with
the delivery system not under pressure: disconnect the pump from the power
supply and open the utility nearest to the pump, keeping it open until it no
longer gives any water.
The special structure of the expansion vessel ensures its quantity and duration
over time, especially of the diaphragm which is typically the component subject
to wear for items of this type. However, in the case of breakage, the entire
expansion vessel must be replaced and exclusively by authorised personnel.

1.3 Technical characteristics

Parameter
Topic
Voltage*
Frequency
ELECTRIC
POWER SUPPLY
Maximum power
Leakage current to earth
³
e.sybox mini
1x220-240 V
1x230 V
1x110-
127 V
50/60 Hz
850 W
<2 mA
Overall dimensions
Empty weight
STRUCTURAL
(excluding packaging)
CHARACTERISTICS
Protection class
Insulation class of the
motor
Maximum head
Maximum flow rate
HYDRAULIC
PERFORMANCE
Priming
Maximum working
pressure
Max liquid temperature
Max environment
temperature
WORKING
Environment temperature
CONDITIONS
of storage
Difference Ambient T. -
Liquid T.
Max. relative humidity
Constant pressure
Protection against dry running
Antifreeze protection
FUNCTIONALITY AND
Anticycling protection
PROTECTIONS
Motor overload protection
Protection against abnormal supply voltages
Protection against excess temperature
*: refer to the technical plate on the pump
2- INSTALLATION
GB
ENGLISH
445x262x242 mm without feet support
14 kg / 30,8 lb
IP x4
F
55 m / 180 ft
80 l/min / 21 U.S. GPM
<5min at 8m / 26 ft
7.5 bar / 109 psi
40 °C / 104 °F
50 °C / 122 °F
-10÷60 °C / 14÷140 °F
< 30 °C / 86 °F
50%
42