Vertical Configuration - DAB E.SYBOX MINI 3 Instructions Pour L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 72
GB
ENGLISH
The system is designed for indoor use: do not install the system outdoors and/
or directly exposed to atmospheric agents.
The system is designed to be able to work in environments where the tem-
perature remains between 1°C and 50°C (on condition that the electric power
supply is ensured: see par. 5.6.8 "anti-freeze function").
Esybox mini operates correctly with a difference between ambient and liquid
temperatures of no more than 30°C (with the ambient temperature higher than
the liquid temperature). Besides this temperature difference, the humidity limit
must not exceed 50%, otherwise there is a risk of condensation forming, which
can cause irreparable damage to the electronic board.
The system is suitable for treating drinking water.
The system cannot be used to pump salt water, sewage, inflammable, corro-
sive or explosive liquids (e.g. petroleum, petrol, thinners), greases, oils or food
productsi.
The system can suck up water with a level that does not exceed the depth of 8
m (he height between the water level and the pump suction mouth).
If the system is used for the domestic water supply, respect the local regula-
tions of the authorities responsible for the management of water resources.
When choosing the installation site, check that:
• The voltage and frequency on the pump's technical data plate correspond to
the values of the power supply system.
• The electrical connection is made in a dry place, far from any possible flood-
ing.
• The earth system must comply with the regulations.
If you are not sure of the absence of foreign bodies in the water to be pumped, install a filter
on the system intake that is suitable for catching impurities.
The installation of a filter on intake causes a decrease of the system's hydraulic
performance proportional to the loss of load caused by the filter itself (generally
the greater the filtering power, the greater the fall in performance).
Choose the type of configuration you intend to use (vertical or horizontal) considering the
connections to the system, the position of the user interface panel, and the spaces avail-
able according to the indications below. Wall installation is possible, see par. 8.2.
43

2.1 - Vertical Configuration

Screw the 4 rubber feet supplied loose in the package into the brass seats in face C. Put
the system in place, taking into account the dimensions in Fig.6.
• The distance of at least 10mm between Face E of the system and any wall is obliga-
tory to ensure ventilation through the grids provided • If you expect to have to
drain the system from its discharge door and not from the system, leave a further
distance sufficient to manoeuvre the drainage cap.
• The distance of at least 10mm between Face B of the system and an obstruction is
obligatory to let out the power supply cable to the mains socket.
• The distance of at least 200mm between Face A of the system and an obstruction is
recommended so as to be able to remove the door and gain access to the technical
compartment.
If the surface is not flat, unscrew the foot that is not touching and adjust its height until it
contacts the surface so as to ensure the stability of the system. The system must in fact
be placed in a safe and stable position, ensuring that its axis is vertical: it must not be in
an inclined position.
Figure 6

Publicité

Table des Matières
loading

Table des Matières