Password For Multipump Systems; Reset And Factory Settings; General System Reset; Factory Settings - DAB e.sybox Instructions Pour L'installation Et L'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 114
Make a note of the number present on the password page, send
a mail with this number to your service centre, in a few days you
will be sent the password to unlock the device.

7.6.21.1 - Password for multipump systems

When the PW is typed in to unlock a device in a set, all the devices are
unlocked.
When the PW is changed on a device in a set, all the devices receive the
change.
When activating protection with a PW on a device in a set (+ and – on page
PW when PW≠0), the protection is activated on all the devices (to make
any change you are asked for the PW).

8 - RESET AND FACTORY SETTINGS

8.1 - General system reset

To reset the system, hold down the 4 keys simultaneously for 2 sec. This
operation is the same as disconnecting the power, waiting for it to close
down completely and supplying power again. The reset does not delete the
settings saved by the user.

8.2 - Factory settings

The device leaves the factory with a series of preset parameters which
may be changed according to the user's requirements. Each change of the
settings is automatically saved in the memory and, if desired, it is always
possible to restore the factory conditions (see Restoring the factory set-
tings par 8.3 – Restoring the factory settings).

8.3 - Restoring the factory settings

To restore the factory values, switch off the device, wait until the display
has switched off completely, press and hold down the "SET" and "+" keys
and turn on the power; release the two keys only when the letters "EE"
appear.
This restores the factory settings (a message and a rereading on EEPROM
of the factory settings permanently saved in the FLASH memory).
Once all the parameters have been set, the device returns to normal op-
eration.
NOTE: Once the factory values have been restored it will be necessary
to reset all the parameters that characterise the system (gains, setpoint
pressure, etc.) as at the first installation.