Energy Yield - Fronius Symo 10.0-3 208-240 Instructions De Service

Masquer les pouces Voir aussi pour Symo 10.0-3 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting range
Factory setting
Since contrast depends on temperature, it may be necessary to adjust the "Contrast" menu
item when environmental conditions change.
Illumination
Initial setting for display illumination
The "Illumination" menu item only applies to the display background illumination.
Setting range
Factory setting

Energy Yield

Setting
-
-
-
-
Setting range
E-meter offset
Specification of a value for the energy supplied that is added to the currently supplied en-
ergy (e.g., the transfer value when an inverter is replaced)
Unit
Setting range
Factory setting
E-meter calibration
Specification of a correction value so that the data shown on the inverter display corre-
spond to the calibrated data shown on the electric meter
Unit
Setting range
Factory setting
Currency
Currency setting
Setting range
Feed-in tariff
Charge rate setting for the energy fed into the grid
Setting range
Factory setting
36
0–10
5
AUTO / ON / OFF
AUTO
AUTO:
The display illumination is activated by pressing any key. If no key is pressed
for 2 minutes, the display backlight goes out.
ON:
The display illumination will be permanently on when the inverter is active.
OFF:
The display illumination will be permanently off.
an OFFSET value for the Total energy display
a measurement correction value for the day, year and total energy display
the currency
the feed-in tariff
E-meter offset/E-meter calibration/Currency/Feed-in tariff
Wh/kWh/MWh
5-digit
0
%
-5.0 to +5.0
0
3-digit, A-Z
2-digit, 3 decimal places
(depends on the country setup)