Contrast
Set the contrast on the inverter display
Setting range
Factory setting
Since contrast depends on temperature, it may be necessary to adjust the
'Contrast' menu item when environmental conditions change.
Illumination
Preset the inverter display illumination
The 'Illumination' menu item only applies to the inverter display background il-
lumination.
Setting range
Factory setting
Energy yield
The following settings can be changed/performed:
-
-
-
-
Setting range
Meter deviation/calibration
Meter calibration
ON:
The Fronius DATCOM operation is always maintained. The inverter
provides an uninterrupted 12 V DC voltage to supply Fronius Solar
Net with power. The display is always active.
IMPORTANT! When the Fronius DATCOM night mode is ON or on
AUTO with connected Fronius Solar Net components, the power
consumption of the inverter at night increases to around 7 W.
OFF:
No Fronius DATCOM operation at night, the inverter therefore does
not require any power to supply electricity to the Fronius Solar Net
at night.
The inverter display is deactivated at night and the Fronius
Datamanager is not available. To activate the Fronius Datamanager,
switch the inverter on the AC side off and back on and press any
function key on the inverter's display within 90 seconds.
0 - 10
5
AUTO / ON / OFF
AUTO
AUTO: The inverter display illumination is activated by pressing any key. If
no key is pressed for 2 minutes, the display backlight goes out.
ON:
The inverter display illumination is permanently on when the invert-
er is active.
OFF:
The inverter display illumination is permanently off.
Meter deviation/calibration
Currency
Feed-in tariff
CO2 factor
Currency / Feed-in tariff