The potential-free switch contact is switched off automatically:
-
-
-
-
To activate the "Energy Manager" function, select "E-manager" and press the "Enter" key.
When the "Energy Manager" function is activated, the "Energy Manager" icon is dis-
played at the top left of the display:
To deactivate the "Energy Manager" function, select another function and press the "Enter"
key.
Information on the Layout of the Switch-on and Switch-off Points
Insufficient difference between the switch-on point and the switch-off point or power fluc-
tuations can cause frequent switching cycles.
To avoid excessive switching on and off, the difference between the switch-on and switch-
off points should be at least 100–200 W.
When selecting the switch-off point, consider the power consumption of the connected us-
er.
When selecting the switch-on point also bear in mind the weather conditions and the ex-
pected solar radiation.
Application Example
Switch-on point = 2000 W, switch-off point = 1800 W
If the inverter supplies 2000 W or more, the potential-free switch contact of the inverter is
switched on.
If the inverter output sinks below 1800 W, the potential-free switch contact is switched off.
Possible applications:
Operation of a heat pump or air-conditioning system, using as much self-produced power
as possible.

Time / Date

Setting of the time, the date, and the automatic daylight saving time adjustment
Setting range
Set time
Set the time (hh:mm:ss or hh:mm AM/PM – depends on the Time display format settings)
Set date
Set the date (dd/mm/yyyy or mm/dd/yyyy – depends on the Date display format settings)
Time display format
Setting range
Factory setting
34
When no current is being fed into the public grid supply by the inverter
When the inverter is switched manually to standby mode
When there is an effective power assignment of 10% of the power rating
When there is insufficient solar radiation
When potential-free NO switch contact is switched off (open contact)
When potential-free NO switch contact is switched on (closed contact)
For setting the format in which the time is displayed
Set time / Set date / Time display format / Date display format /
Daylight saving time
12 / 24 hour clock
Depends on the country setup