Class 5 Status Codes; Class 6 Status Codes - Fronius Symo 10.0-3 208-240 Instructions De Service

Masquer les pouces Voir aussi pour Symo 10.0-3 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Class 5 Status
Class 5 status codes generally do not impair feed-in mode, but can lead to limitations in
Codes
feed-in mode. They will be displayed until the status code is acknowledged by pressing a
key (the inverter, however, continues working normally in the background).
Code
Description
502
Insulation fault on solar mod-
ules
509
No feed-in within the last 24
hours
515
No internal communication
with filter
516
Communication with memory
unit not possible
Power derating due to exces-
517
sive temperature
518
Internal DSP malfunction
519
Communication with memory
unit not possible
520
No feed-in within the last 24
hours from MPPT1
522
DC low String 1
523
DC low String 2
558,
Function incompatibility (one
559
or more PC boards in the in-
verter are not compatible with
each other, e.g.,after PC board
replacement)
Power derating due to over-fre-
560
quency
564
Function incompatibility (one
or more PC boards in the in-
verter are not compatible with
each other, e.g.,after PC board
replacement)
*) If status code persists: Contact a Fronius-trained service technician
**) If this status code keeps recurring, contact your system installer
Class 6 Status
Class 6 status codes may require the intervention of a trained Fronius service technician.
Codes
50
Behavior
Warning message is
shown on the display
Warning message is
shown on the display
Warning message on
the display
Warning message of
memory unit
A warning message is
shown on the display
when a power derating
occurs
Warning message on
the display
Warning message of
memory unit
Warning message is
shown on the display
Warning message on
the display
Warning message on
the display
Displayed when grid fre-
quency is too high. The
power is reduced.
Warning message on
the display
Remedy
**)
Acknowledge status code;
Check whether all conditions for
problem-free grid power feed opera-
tion are met (e.g., whether solar mod-
ules are covered with snow); **)
*)
*)
Purge cooling air openings and cool-
ing elements if necessary;
Error is corrected automatically; **)
*)
*)
Acknowledge status code;
Check whether all conditions for
problem-free grid power feed opera-
tion are met (e.g., whether solar mod-
ules are covered with snow); *)
*)
Update inverter firmware; *)
As soon as the grid frequency returns
to the permissible range and the in-
verter is back to normal operation, the
error is automatically corrected; **)
Update inverter firmware; *)

Publicité

Table des Matières
loading