Denomination Terminals
(1)
Description
Power supply Power 101 Source
1
230 V~102
Power supply Power 201 Source
2
230 V~202
Sensing inputs N (103) Neutral
1
source
L3 (104) Phase 3
L2 (105) Phase 2
L1 (106) Phase 1
Sensing inputs L1 (203) Phase 1
2
source
L2 (204) Phase 2
L3 (205) Phase 3
N (206) Neutral
Commands
207
Commands inputs Common terminal
208
Standby source transfer control input (CTS)
209
Remote test on load input
210
DC power supply for 2I / 2O
Genset
73
Genset start / stop relay - 2 stable positions
start signal
(2)
74
Programmable state - factory setting = NO, close to start 5A AC1 / 250 V
Control
313
Control activation
(Impulse /
if closed with 317
contactor
314
Position II order if closed with 317
mode to
315
Position I order if closed with 317
change
316
Position 0 order if closed with 317
programming) 317
Specific voltage supply
Common control terminals 313 to 316
Remote interface RJ
ATyS D10 or D20 connection
conection
Position
13
Common I - 0 - II
auxiliary
14
AC position I NO
contacts
24
AC position II NO
34
AC position 0 NO
Auxiliary
43
Auto / manu selector position
contacts
44
Closed in automatic position
/ AUT &
53
Padlocked information
Padlock
54
Closed if padlock is in place
Fault
63
Relay closed when product is faulty
relay
64
(if product is powered)
Second
81
Common AC position I
auxiliary
82
AC position I NC
contact
84
AC position I NO
(option)
91
Common AC position II
92
AC position II NC
94
AC position II NO
Option
0
Connection RS485
Communication -
+
Option
I13 +
Input
2 Inputs /
I14 -
Function according to programming
2 Outputs
I23 +
Input
I24 -
Function according to programming
O13
Output Relay
O14
Function according to programming
O23
Output Relay
O24
Function according to programming
Voltage and frequency sensing precision: 1 %
(1) Terminal numbers can differ depending on voltage sensing and power supply kit configuration.
(2) Refer to programming, Setup, to modify relay state.
(3) It is recommended to power 2I / 2O modules from terminals 207-210 (refer to connection diagram).
SOCOMEC - Réf.: 531 848 F
1
2
Automatic Transfer Switch ATyS
CONNECTIONS
Characteristics
220 to 240 Vac ±20 %
500 Vac (phase-phase)
maximum
288 Vac (phase-neutral)
maximum
500 Vac (phase-phase)
maximum
288 Vac (phase-neutral)
maximum
Do not connect to any
power supply
Dry contact
Do not connect to any
power supply
Maximum distance 3 m.
5A AC1 / 250 V
5A AC1 / 250 V
5A AC1 / 250 V
5A AC1 / 250 V
To power from 10 to 30 Vdc
(3)
(3)
To power from 10 to 30 Vdc
5A AC1 / 250 V
Recommended
section
2
1.5 mm
1.5 mm
2
1.5 mm
2
2
1.5 mm
4 mm
2
1.5 mm
2
RJ45 8 / 8
1.5 mm
2
1.5 mm
2
1.5 mm
2
2
1.5 mm
1.5 mm
2
2
1.5 mm
1.5 mm
2
93