The angle units used to show the inclination can be set to
degrees, percent or mm/m. The currently selected angle
unit is shown in a black square.
6.4.4 Expert mode on / off
When the expert mode is active, the timer, min/max
and measuring reference can be combined for use with
all functions. In addition, supplementary information is
shown for the following functions: Area, Volume, Py-
thagoras, Trapezoidal Area, Indirect Horizontal Distance
and Indirect Vertical Distance. If a scale has been set in
the "Settings" menu, this can be shown in export mode.
The choices available are shown at the top edge of the
display.
6.4.5 Changing the favorites bar
Changes can be made to the favorites bar in these
settings. The favorites bar provides quick access to the
most frequently used functions.
1.
Use the right or left arrow buttons to select the
function you wish to change.
2.
Confirm by pressing the "Measure" button.
3.
Use the right or left arrow button to select the desired
function.
4.
Confirm by pressing the "Measure" button.
6.4.6 Activating the Scale function
This function allows you to set the desired scale.
1.
Use the left or right arrow buttons to set the desired
scale.
2.
Confirm the applicable number by pressing the
"Measure" button.
3.
Select the "tick" symbol to confirm the value.
NOTE Expert mode must be active in order to be
able to make use of the Scale function.
6.4.7 Switching the signal tone on / off
The signal tone can be switched on or off in the signal
tone settings.
1.
Use the right or left arrow button to select the desired
setting.
2.
Confirm by pressing the "Measure" button.
6.4.8 Permanent laser mode
When in permanent laser mode, a measurement is taken
each time the "Measure" button is pressed. The laser is
not deactivated after the measurement is taken. In this
mode, several measurements can be taken very quickly,
one after the other, with only a few presses of the button.
The corresponding symbol is shown in the status bar of
the main screen.
6.4.9 Show inclination in the display, on / off
In this menu you can select whether the angle of in-
clination is to be shown in the main screen (activate /
deactivate).
6.4.10 Calibrating the inclination sensor
In order to achieve greatest possible accuracy when
making inclination measurements, the inclination sensor
must be calibrated at regular intervals. If the tool has
suffered an impact or has been subjected to temperature
fluctuations, the inclination sensor must be recalibrated.
Calibration is carried out in 3 steps.
1.
To begin calibration, select the inclination sensor
calibration symbol.
2.
Lay the tool on a horizontal surface and then press
the "Measure" button.
3.
Rotate the tool horizontally through 180° and press
the "Measure" button again.
NOTE The inclination sensor is now calibrated.
6.4.11 Information about the tool
Here you will find information about the tool, such as the
software version, hardware version and serial number.
6.4.12 Resetting to the default settings
This function can be used to reset the tool to the default
settings.