Troubleshooting (continued)
Display
Code
Message
F43
F43 EYE/
F46
EDG1 BLK
F49
F46 EYE/
EDG2 BLK
F49 EYE/
EDG3 BLK
F51
F51 INP1
F52
BLOCK
F52 INP1
F53
CMND
F54
F53 INP2
F55
BLOCK
F56
F54 INP2
CMND
F57
F58
F55 INP3
BLOCK
F56 INP3
CMND
F57 INP4
BLOCK
F58 INP4
CMND
Possible
Description
Causes
Monitored eyes/
See sections for
edges 1/2/3
F41/F42/F44/
were blocked or
F45/F47/F46 as
missing when
applicable
the door was
commanded to
move.
Unmonitored
Obstruction
eye/edge device
in doorway
triggered for 3
is blocking
minutes or more
unmonitored eye/
on input 1/2/3/4,
edge device
or blocked when
door motion was
requested
Improperly
configured input
Incompatible
device is being
used
Wiring fault to
device
Damaged device
Damaged
powerhead main
board
Diagnosis
Check for obstructions
Check system settings item
in the menu to check the
device type setting for the
input
INP1/2/3/4 inputs are
compatible with dry-contact
type devices. Ensure the
device being used is a dry-
contact type device.
Check wiring for short or
open circuit
Ensure wires are wired into
correct terminals
Swap device with known-
good device
Disconnect unmonitored
eye/edge. Open circuit
condition is equivalent to an
unobstructed unmonitored
eye/edge device.
76
Resolution
If obstructions are
present, remove the
obstruction
Ensure the device type
matches the device that
is actually installed
If the device is
incompatible, replace
with one that is, or move
the device to another
input which is compatible
with the device
Correct wiring faults
If a known-good device
works, replace the faulty
device
If the main board still
detects an obstruction
with no device
connected, power cycle
the operator.
If the problem persists,
reset to factory defaults
and configure again.
If problem still persists,
replace the powerhead