Auxiliary Relays Accessory Kit (AUXREL)
Configure the Relay Adapter
AUXILIARY RELAYS
Aux Relay Switches: Set the AUX RELAY switches as needed to obtain the desired function as shown below.
J6 Input: Communicator bus connects control board, expansion board, or relay adapter board.
J7 Input: Communicator bus connects control board, expansion board, or relay adapter board.
AUX24: Supplies +24Vdc up to 1AMP to wired accessories.
The expansion board and relay adapter board provide Normally Open (N.O.) and Normally Closed (N.C.) relay contacts
to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only.
Function of relay contact activation determined by switch settings.
SWITCH SETTINGS
AUX RELAY
SETTING
1
Off (no
OFF
feature
selected)
Open Limit
OFF
Switch
Closed Limit
OFF
Switch
Door Motion
OFF
AUX RELAY 1
2
3
OFF
OFF
Relay always off. Use this Aux Relay setting to conserve battery power.
OFF
ON
Energizes at open limit. Use with SAMS (Sequenced Access Management
System, jointly with door).
ON
OFF
Energizes when not at close limit. For an additional audible or visual display,
connect an external light (low voltage).
ON
ON
Energizes when motor is on. For an additional audible or visual display,
connect an external buzzer or light (low voltage).
AUXREL - RELAY ADAPTER BOARD
56
AUX RELAY 2
N.C
COM
N.O
N.C
COM
N.O