Télécharger Imprimer la page

LiftMaster MAXUM JDC Serie Manuel D'installation page 32

Publicité

Wiring Diagram
To prevent possible SERIOUS INJURY or DEATH:
Disconnect electric power and/or battery BEFORE
installing, performing ANY adjustments, or maintenance.
Installation and ALL maintenance MUST be performed
by a trained door systems technician.
TRANSFORMER BOX, 2200
Orange
Orange
Transformer
White
White
Rectifier PCBA
Brake Solenoid
Brown
Black
CHASSIS
BATTERY BOX
+
-
+
-
24Vdc
Battery Accessory SKUs:
DC7AH- 7.0Ah Batteries
TRANSFORMER BOX, 1200
Rectifier
Orange
Orange
Transformer
Rectifier
White
White
1200 Model: Two Rectifiers
TRANSFORMER BOX, 700
Rectifier
Orange
Orange
Transformer
700 Model: One Rectifier
Optional Accessories 
 WARNING
For continued protection against fire:
Replace ONLY with fuse of same type and rating.
Black
Red
Factory
Wired
Conduit
Battery Power Conduit
WARNING
Observe Voltage
Blue
Purple
Gray
Brown
Black Black
Red Red
30
30
Replaceable 30A
DC Input from
Automotive Fuses
Transformer/Rectifier
(One pair for 700, two pairs for 1200)
WARNING: May spark when connected
Motor Power
Jumpers must be
placed if cables
are not connected
Battery Power Conduit
Factory
Wired
Conduit
Motor
Gray
Encoder
Module
Black
Hoist Switch
32
AC JUNCTION BOX
L3
Conduit
L2
120VAC or 240VAC Input
L1
Field Wiring
Conduit
Green
Black
White
AC Input
Green
White
Plug transformer connector into
Black
the appropriate voltage that
matches the applied AC voltage
OR
CLASS 2 SUPPLY +24V
Accessories may connect to the regular or switched port.
ACCESSORY POWER 24VDC, 1A
DRY CONTACT NOTE:
INTR LOCK jumper MUST
be removed if switch is added.
Ancillary (non-monitored) devices
and dry contact inputs NO/NC.
NOTE: STOP - CMN jumper MUST be
SBC
removed if a 3-Button Station is added.
OPEN
Close - Output 2 (Blue)
CLOSE
Open - Output 1 (Green)
STOP
Black
CABLE TENSION
MONITORS
Photo Eyes
CPS-U, CPS-UN4,
CPS-OPEN4, OES-RD16
LC36M
Resistive Edge
Field Wiring
Conduit
To use 3-Phase Power, tap
any two phase legs. Use
proper phase balancing.
Optional Stepdown Transformer
XF600VAC7, XF600VAC12, XF600VAC22
XF208VAC7, XF208VAC12, XF208VAC22
600VAC to 120VAC
OR
208VAC to 120VAC
Select appropriate transformer
for the operator model size
480VAC
Input
480V comes factory wired
Brown
Blue
50-HERK2
White/Black
Brown
To EYE/EDGE
Blue
White
To CMN
White/Black
White
Tx
Rx
Light Curtain
LC36M

Publicité

loading