Technical data
Gross weight incl. connections and
media
Ground clearance
Operation
Levelling types
Emergency stop
Emergency operation
System test
Hydraulic assembly
Engine rating
Supply voltage
Maximum pressure: extending
Maximum pressure: retracting
Operating temperatures:
Volume tank
62
Approx. 56 kg depending on the vehicle connection variant
160-180 mm is recommended
Touch TCU manual operating device
Automatic, semi-automatic, manual
Yes: In the TCU, ignition on
Yes: integrated in wall mount and manual pump
Yes: test of all system functions before setting off
Underfloor installation or installation in the vehicle
2 x 700 W per assembly
12 VDC (min.: 9 VDC; max: 14 VDC)
210 bar
190 bar
-15 °C to 60 °C
4.2 L