1.2.c. ELECTRICAL AND PNEUMATIC CONNECTIONS
The dimensions of the electric hook-up used must be suitably sized in relation to:
• the electric power absorbed by the machine, indicated on its data plate (Fig. 1);
• the distance between the machine and the power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10% during start-up) compared with the rated voltage
specified on the data plate.
- The operator must:
• it a power plug on the power supply lead in compli-
ance with the relevant safety standards;
• connect the machine to its own electrical connection
- A, Fig. 2 - and fit a differential safety circuit-breaker
with 30 mA residual current;
• it fuses to protect the power supply line, rated as
indicatedonthegeneralwiringdiagraminthismanual;
• connect the machine to an industrial socket; the
machine must not be connected to domestic sockets.