Specifications and Characteristics - RP793xA, RP794xA
Specifications - RP793xA, RP794xA
Supplemental Characteristics - RP793xA, RP794xA
Common Characteristics
AC Input Efficiency, Power Factor, and THD
Output Impedance Graphs
Inductive Load Boundary for Constant Current (CC) Operation
Capacitive Load Boundary for Constant Voltage (CV) Operation
Measurement Accuracy and Resolution
Excessive Dynamic Protection
Output Quadrants
Specifications - RP793xA, RP794xA
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C
after a 30-minute warm-up period. Specifications apply at the output terminals, with the sense
terminals connected to the output terminals (local sensing).
Specification
DC Ratings
Voltage source:
Current source and sink:
Power:
Output ripple & noise
CV peak-to-peak: 1
CV rms: 2
Load regulation
Voltage:
Current:
Voltage programming &
measurement accuracy 3
Current programming &
measurement accuracy: 3
Transient response 4
Recovery Time:
Settling band:
1 From 20 Hz to 20 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
2 From 20 Hz to 10 MHz (-3dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded
3 Percent of value + offset; at 25°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year, see
with a load lead voltage drop of up to 1V per lead - see
4 Time to recover to within the settling band following a step change from 40% to 90% of full load with a 35 μs current rise time
Keysight RP7900 Series Operating and Service Guide
RP7931A,
RP7932A,
RP7941A
RP7942A
0 to 20 V
0 to 80 V
0 to ±400 A
0 to ±125 A
0 to ±5 kW
0 to ±5 kW
30 mV
80 mV
3 mV
8 mV
1 mV
3 mV
25 mA
13 mA
0.02% + 2 mV
0.02% + 8 mV
0.04% + 45 mA
0.03% + 13 mA
300 µs
300 µs
0.2 V
0.8 V
Wire Size
for additional information about load lead voltage drop
RP7933A,
RP7935A,
RP7943A
RP7945A
0 to 20 V
0 to 80 V
0 to ±800 A
0 to ±250 A
0 to ±10 kW
0 to ±10 kW
30 mV
80 mV
3 mV
8 mV
1 mV
3 mV
50 mA
25 mA
0.02% + 2 mV
0.02% + 8 mV
0.04% + 90 mA
0.03% + 25 mA
300 µs
300 µs
0.2 V
0.8 V
Calibration
1 Quick Reference
RP7936A,
RP7946A
0 to 160 V
0 to ±125 A
0 to ±10 kW
200 mV
20 mV
6 mV
13 mA
0.02% + 16 mV
0.03% + 13 mA
300 µs
1.6 V
Interval;