Parameter
POSitive|NEGative, *RST POSitive
Set current slope to negative (falling edge): TRIG:ACQ:CURR:SLOP NEG
Set voltage slope to negative (falling edge): TRIG:ACQ:VOLT:SLOP NEG
TRIGger:ACQuire:INDices[:DATA]?
Returns the indices into the acquired data where triggers were captured during the acquisition. The
number of indices returned is the same as the value returned by TRIGger:ACQuire:INDices:COUNt?
Parameter
(none)
Returns the number of indices: TRIG:ACQ:IND?
TRIGger:ACQuire:INDices:COUNt?
Returns the number of triggers captured during the acquisition.
Parameter
(none)
Return the number of triggers: TRIG:ACQ:IND:COUN?
TRIGger:ACQuire:TOUTput[:ENABle] 0|OFF|1|ON
TRIGger:ACQuire:TOUTput[:ENABle]?
Enables measurement triggers to be sent to a digital port pin. The digital port pin must be configured
as trigger output before it can be used as a trigger source (see
Parameter
0|OFF|1|ON, *RST OFF
Enable sending measurement triggers to digital pins: TRIG:ACQ:TOUT ON
TRIGger:ACQuire:SOURce <source>
TRIGger:ACQuire:SOURce?
Selects the trigger source for the acquisition system:
BUS
Selects a remote interface trigger command.
CURRent1
Selects an output current level.
EXTernal
Selects ALL digital port pins that have been configured as trigger sources.
PIN<1-7>
Selects a digital port pin configured as a trigger input.
TRANsient1
Selects the transient system as the trigger source.
VOLTage1
Selects an output voltage level.
Keysight RP7900 Series Operating and Service Guide
5 SCPI Programming Reference
Typical Return
POS or NEG
Typical Return
<time>
Typical Return
<time>
External Trigger
Typical Return
0 or 1
I/O).
245