Program the list levels
Example 1 If you are programming a voltage pulse or pulse train, set the amplitude of the pulse. For
example, to generate a pulse with an amplitude of 15 V, program the amplitude for the pulse (step 0),
and the amplitude for the off time (step 1).
Front Panel Menu Reference
Select Transient\List\Config.
Select List Step 0 (the pulse) and enter a voltage value
of 15. Press Select.
Select List Step 1 (the off time) and enter a voltage
value of 0. Press Select. Use the up/down arrows to
select the next step.
Example 2 If you are programming an arbitrary voltage list, specify the amplitudes for the list. The
order in which the values are entered determines the order in which the values will be output. To
generate the voltage list shown in the figure, a list may include the following values: 9, 0, 6, 0, 3, 0:
Front Panel Menu Reference
Select Transient\List\Config.
Select the List Step number and enter a voltage value.
Press Select.
Repeat this for each step. Use the up/down arrows to
select the next step.
Program the dwell times
Example 1 If you are programming a voltage pulse, set the dwell time of the pulse width. Also specify
the dwell of the off time. This is necessary if you are generating a pulse train, since the off time
determines the time between pulses. To generate a pulse with a pulse width of 1 second and an off
time of 2 seconds, use:
Keysight RP7900 Series Operating and Service Guide
4 Using the Regenerative Power System
SCPI Command
To program the amplitude for step 0 (the pulse) and
step 1 (the off time):
LIST:VOLT 15,0
SCPI Command
To program a voltage list of 5 steps:
LIST:VOLT 9,0,6,0,3,0