en
15.3.4
Error type E or F
1
2
3
4
5
6
7
8
9a
9b
Fig. 57: Error type E, flowchart
1
2
3
4
5
Fig. 58: Error type F, flowchart
6.0.0.0
E000
Fig. 59: Acknowledging error type E or F
164
Program step/query
1
2
3
4
5
6
7
8
9a
9b
Table 32: Error type E
Program step/query
1
2
3
4
5
Table 33: Error type F
Acknowledging error type E or F:
•
To change to menu mode, press the operating button. Menu number <6.0.0.0> flashes on
12.3
the display.
•
Press the operating button again. The error is acknowledged, and the status page is dis-
played.
Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA-D, Wilo-Stratos GIGA B • Ed.01/2024-02
NOTICE
The error will be acknowledged automatically if the cause of the error is
eliminated.
Contents
•
Error code is displayed
•
Pump goes into emergency operation
•
Error counter is increased
Error matrix AC or HV?
•
SSM is activated
Error criterion fulfilled?
Error acknowledged?
Error matrix HV and > 30 min?
•
SSM is activated
End; auto control (twin-head pump) resumes
End; auto control (single pump) resumes
Yes
No
Contents
•
Error code is displayed
•
Error counter is increased
Error criterion fulfilled?
Error acknowledged?
End; auto control resumes
Yes
No