No.
E020
E021
Motor errors
E023
E025
E026
E030
E031
E032
Electronic
module error
E033
E035
158
Error
Cause
Excessive
Motor over-
winding tem-
loaded
perature
Motor ventila-
tion limited
Water temper-
ature too high
Motor overload Duty point
outside duty
chart
Deposits in the
pump
Short circuit/
Motor or elec-
earth leakage
tronic module
defective
Faulty contact
Electronic
module has no
contact to mo-
tor
Winding inter-
Motor faulty
rupted
WSK or PTC in-
Motor faulty
terrupted
Excessive elec-
Limited air
tronic module
supply to the
temperature
heat sink of the
electronic
module
Excessive tem-
Ambient tem-
perature in hy-
perature too
brid/power unit
high
Intermediate
Voltage fluctu-
circuit under-
ations in the
voltage
mains
Intermediate
Voltage fluctu-
circuit over-
ations in the
voltage
mains
DP/MP: mul-
Multiple in-
tiple instances
stances of
of same iden-
same identity
tity
Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA-D, Wilo-Stratos GIGA B • Ed.01/2024-02
Remedy
Error type
Allow motor to
B
cool down,
check settings,
check/correct
duty point.
Provide unob-
structed air ac-
cess
Lower water
temperature
Check/Correct
B
duty point
Request cus-
tomer service
Request cus-
A
tomer service
Request cus-
A
tomer service
Request cus-
tomer service
Request cus-
B
tomer service
Provide unob-
B
structed air ac-
cess
Improve room
B
ventilation
Check elec-
F
trical installa-
tion
Check elec-
F
trical installa-
tion
Reassign main
E
and/or partner
pump (see sec-
tion "Twin-
head pump in-
stallation / y-
pipe installa-
tion")
A
A
A
A
A
A
A
D
D
E