8.4
Terminals
SSM
Fig. 26: Control terminals
Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA-D, Wilo-Stratos GIGA B • Ed.01/2024-02
Secure cable glands tightly.
Ensure that no drips can run into the electronic module:
Bend the cables into a drain loop near the threaded cable gland
Unused cable glands should be sealed with the sealing washers provided and screwed
tight.
The mains cable should be laid in such a way that it can under no circumstances come into
contact with the pipe and/or the pump and motor housing. When pumps are used with fluid
temperatures above 90°C, a mains cable with suitable thermal resistance must be used.
Note additional earthing!
Tightening torques for union nuts of the threaded cable glands
Thread
M12x1.5
M16x1.5
M20x1.5
M25x1.5
M40x1.5
Table 11: Tightening torques for threaded cable glands
Control terminals
Please also see the following "Terminal assignment" table.
Power terminals (mains connection terminals)
Fig. 27: Power terminals
SBM
Please also see the following "Terminal assignment" table.
Additional earthing
Fig. 28: Additional earthing, from 11 kW motor power
Tightening torque
[Nm] ± 10 %
3.0
6.0
8.0
11.0
16.0
11 ... 22 kW:
DANGER
Danger of death due to electrical current!
As motors from 11 kW generate more leakage current, improper electrical
connections can lead to fatal electric shock!
• Motors from 11 kW must be additionally connected to a reinforced
earth connection.
en
Installation information
1x threaded cable gland M12
reserved for connecting
cable for an optional differ-
ential pressure sensor
121